Quick Air-Lock for rapid decontamination and transfer (SARA)
SKAN AG
Productivity and Flexibility
The airlock achieves a very short decontamination time.
It is especially useful for frequent transfers in production into an already sterile environment for items that are not autoclavable.
- Simple operation with clearly arranged control and monitoring console
- Application specific loading and unloading system
- Comfortable operating height, easy cleaning
- Independent SPS controls
- Integrated and fully automated H2O2 decontamination system SIS-A
- H2O2 surface decontamination from 15 minutes inclusive purging to <1ppm
- Guaranteed spore reduction from > 106
- Optimally combined with filling line isolators or personal protection isolators
Technology of Quick Airlock
- GMP Cleanroom Class Grade A, ISO 5
- Twice filtered inlet and outlet air (HEPA H14)
- DEHS connection for ,,in situ" testing
- Unidirectional airflow over the entire loading surface
- Automatic leak test
- Pneumatic gasket system
- Controlled pressure differential between room and isolator
- Continuously welded stainless steel construction
- Interior chamber of AISI 316L, polished to 0.8 µm
- Exterior AISI 304, polished to 1.2µm
- Single window pane of safety glass ESG with pneumatic gaskets
- Simple to clean, floor level unloading
- Clearly defined separation of the attachment to the isolator
Product Features
- H2O2 Cycle development with validation guarantee
- HEPA filter protection system for the use of liquids in the unit
|
Size
|
Measurements [mm]
|
Air volume [m3/h]
|
|
Customer determined
|
L 500 x T 600 x H 500
|
~ 560
|
|
Interior measurement (Chamber)
|
600 x 750 x 500
|
> 600
|
DOWNLOAD MORE INFORMATION
 |
Decontamination Transfer Chamber |
The essential function of a decontamina-tion transfer chamber is the transfer of goods from a room with a lower clean-room class to a room with a higher cleanroom class with simultaneous decontamination.
|
263.46 KB |
Download |
E-mail page to friend